PHOTOELECTRIC SENSING TECHNOLOGY
INSECT SCREEN SENSOR PROTECTION
TEST/HUSH FUNCTION
AUSTRALIAN STANDARDS AS3786:2014
5 YEAR WARRANTY
STANDBY CONDITION
The red LED will flash every 40 seconds to indicate that the smoke alarm is operating properly.
ALARM CONDITION
When the alarm senses products of combustion and goes into alarm the red LED will flash one flash per second. The flashing LED and pulsating alarm will continue until the air is cleared. When units are interconnected, only the red LED of the alarm that senses the smoke or is being tested (the originating unit) will flash. All other units in the interconnected system will sound an alarm but their red LED’s will NOT flash.
HUSH MODE
The red LED will illuminate for every 8 seconds, indicating the smoke alarm is in the Hush Mode. Pressing and releasing the Test button the smoke alarm will enter Hush mode
INSTALLATION OF THE SMOKE ALARM
The HOMEGUARD smoke alarm is easy to install. The unit is fitted on a base plate with multiple fixing holes. The smoke alarm is connected to power on a 3 pin terminal block on the base plate. The smoke alarm easily slides on the base plate for positive power connection.
This alarm cannot be operated from power derived from a square wave, modified square wave or modified sine wave inverter. These type of inverters are sometimes used to supply power to the structure in off grid installations, such as solar or wind derived power sources. These power sources produce high peak voltages that will damage the alarm.
Installing smoke alarm on its own subcircuit will avoid false alarms and nuisance chirping that may be caused by electromagnetic interferences from other electrical equipment.
The HOMEGUARD HG3000 is not designed to be interconnected with other brands or products. Should other products need to be interconnected for a complete system, please contact PSA PRODUCTS for more information.
- 240VAC with 9VDC battery backup
- Photoelectric Technology Design
- Insect screen over sensor chamber
- Operate as single or inter-connect up to 24 units
- Easy slide base plate
- Suitable for Ceiling or Wall mounting
- Single Test and Hush button
- Anti-tamper feature
- Loud 85dBA sounder ISO8201 sound pattern.
- Tested and Approved to AS3786:2014
Additional information
Weight | 1 kg |
---|---|
Model | HG3000 |
Dectection Method | PHOTOELECTRIC / PHOTO-OPTICAL SENSING TECHNOLOGY |
Operations | Stand-alone or interconnect up to 24 units |
Power Requirments | 240V AC 50 Hz sine wave supply |
Power Backup | 9Vdc Battery |
Rating | 80mA max per alarm |
Alarm Sound | 85db at 3m |
Hush Function | 10-15 minutes. Red LED Flash Every 8-10 seconds |
Low Battery Indication | Sounds a chirp at 40 second intervals, in addition to red LED flashing |
Alarm Duration | As long as smoke is presents, unit automatically resets when smoke clears |
Alarm Indication | Flashing red LED indicator every seconds |
Temperature Range | 4℃ to 45℃ |
Humidity Range | Up to 95% relative humidity (RH) |
SIze (W x H ) | 120 x 40mm |
Wiring | Hard wire 3 pin terminal block |
LED | Green, power indicator. Red, alarm indicator |
Warranty | 5 Years – limited warranty excludes battery |
Compliance | Activfire approved and listed to AS3786: Australian standards certified product. Australian Electrical Authority Approval. RCM. Manufactured under ISO9001 |
This newer model of the detector was compatible with my existing fittings meaning it did not need to be rewired. Simply plug and play.
Reasonable delivery fees meant they got my business.
Quick delivery means I’ll be back.
Is this HG3000 compatible with the older model HG2000?
Hi Andrew,
Yes, you can use the existing plug/base plate for the HG2000, simply unplug the old smoke alarm and plug in the HG3000.
Very good product and fast order process